Product Detail
Product Tags
Property |
Test Method |
Standard Value |
Operation Temperature |
IEC 216 |
-45℃ to 105℃ |
Tensile Strength |
ASTM-D-2671 |
≥12MPa |
Elongation at Break |
ASTM-D-2671 |
≥300% |
Tensile Strength after Aging |
ASTM-D-2671 |
≥10MPa (130℃,168hrs) |
Elongation at Break |
ASTM-D-2671 |
≥230% (130℃,168 hrs) |
after Aging |
Dielectric Strength |
IEC 60243 |
≥20kV/mm |
Stress Cracking Resistance |
ASTM-D-1693 |
No cracking |
Volume Resistivity |
IEC 60093 |
≥1×1014Ω·cm |
Fungus and Decay Resistance |
ISO 846 |
Pass |
Longitudinal Shrinkage |
ASTM-D-2671 |
≤10% |
Eccentricity |
ASTM-D-2671 |
≤30% |
Water Absorption |
ISO 62 |
≤0.5% |
Size |
D/mm |
L/mm |
W/mm |
As supplied |
After recovery |
As supplied |
After recovery |
11/6 |
≥11 |
≤6 |
≥22 |
0.7±0.1 |
≤1.1 |
16/8 |
≥16 |
≤8 |
≥70 |
1.2±0.1 |
≤2.2 |
20/8 |
≥20 |
≤8 |
≥70 |
1.2±0.1 |
≤2.2 |
25/11 |
≥25 |
≤11 |
≥80 |
1.2±0.1 |
≤2.3 |
32/16 |
≥32 |
≤16 |
≥90 |
Previous: